Silicon Labs /SiM3_NRND /SIM3L166_C /ACCTR_0 /STATUS

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as STATUS

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (NOT_SET)DIRCHGI 0 (NOT_SET)OVFI 0 (NOT_SET)CMP0I 0 (NOT_SET)CMP1I 0 (NOT_SET)TRANSI 0 (NOT_SET)QERRI 0 (NOT_SET)FLSTOPI 0 (NOT_SET)FLSTARTI 0 (DISABLED)DIRCHGIEN 0 (DISABLED)OVFIEN 0 (DISABLED)CMP0IEN 0 (DISABLED)CMP1IEN 0 (DISABLED)TRANSIEN 0 (DISABLED)QERRIEN 0 (DISABLED)FLSTOPIEN 0 (DISABLED)FLSTARTIEN 0 (LOW)IN0 0 (LOW)IN1 0 (LOW)IN0PREV 0 (LOW)IN1PREV 0 (ST0)STATE 0 (COUNTER_CLOCKWISE)DIRF 0 (NOT_SET)FLF 0DIRHIST0 (LOW)CMP0OUT 0 (LOW)CMP1OUT

IN1PREV=LOW, IN0PREV=LOW, FLSTOPIEN=DISABLED, CMP1I=NOT_SET, DIRF=COUNTER_CLOCKWISE, STATE=ST0, CMP1OUT=LOW, IN1=LOW, IN0=LOW, QERRI=NOT_SET, DIRCHGI=NOT_SET, TRANSI=NOT_SET, CMP1IEN=DISABLED, FLSTARTIEN=DISABLED, FLF=NOT_SET, TRANSIEN=DISABLED, QERRIEN=DISABLED, CMP0IEN=DISABLED, OVFIEN=DISABLED, FLSTARTI=NOT_SET, FLSTOPI=NOT_SET, DIRCHGIEN=DISABLED, CMP0I=NOT_SET, CMP0OUT=LOW, OVFI=NOT_SET

Description

Pulse Counter Status

Fields

DIRCHGI

Direction Change Interrupt Flag.

0 (NOT_SET): A direction change did not occur.

1 (SET): A direction change occurred.

OVFI

Counter Overflow Interrupt Flag.

0 (NOT_SET): Neither of the counters overflowed.

1 (SET): One of the counters overflowed.

CMP0I

Digital Comparator 0 Interrupt Flag.

0 (NOT_SET): A digital comparator 0 and counter 0 match did not occur.

1 (SET): A digital comparator 0 and counter 0 match occurred.

CMP1I

Digital Comparator 1 Interrupt Flag.

0 (NOT_SET): A digital comparator 1 and counter 1 match did not occur.

1 (SET): A digital comparator 1 and counter 1 match occurred.

TRANSI

Integrator Transition Interrupt Flag.

0 (NOT_SET): An integrator output transition did not occur.

1 (SET): An integrator output transition occurred.

QERRI

Quadrature Error Interrupt Flag.

0 (NOT_SET): A quadrature error did not occur.

1 (SET): A quadrature error occurred.

FLSTOPI

Flutter Stop Interrupt Flag.

0 (NOT_SET): A flutter detection end event did not occur.

1 (SET): A flutter detection end event occurred.

FLSTARTI

Flutter Start Interrupt Flag.

0 (NOT_SET): A flutter detection start event did not occur.

1 (SET): A flutter detection start event occurred.

DIRCHGIEN

Direction Change Interrupt Enable.

0 (DISABLED): Disable direction change as an interrupt or wake up source.

1 (ENABLED): Enable direction change as an interrupt or wake up source.

OVFIEN

Counter Overflow Interrupt Enable.

0 (DISABLED): Disable counter overflows as an interrupt or wake up source.

1 (ENABLED): Enable counter overflows as an interrupt or wake up source.

CMP0IEN

Digital Comparator 0 Interrupt Enable.

0 (DISABLED): Disable comparator 0 as an interrupt or wake up source.

1 (ENABLED): Enable comparator 0 as an interrupt or wake up source.

CMP1IEN

Digital Comparator 1 Interrupt Enable.

0 (DISABLED): Disable comparator 1 as an interrupt or wake up source.

1 (ENABLED): Enable comparator 1 as an interrupt or wake up source.

TRANSIEN

Integrator Transition Interrupt Enable.

0 (DISABLED): Disable integrator transitions as an interrupt or wake up source.

1 (ENABLED): Enable integrator transitions as an interrupt or wake up source.

QERRIEN

Quadrature Error Interrupt Enable.

0 (DISABLED): Disable quadrature error as an interrupt or wake up source.

1 (ENABLED): Enable quadrature error as an interrupt or wake up source.

FLSTOPIEN

Flutter Stop Interrupt Enable.

0 (DISABLED): Disable flutter detection end events as an interrupt or wake up source.

1 (ENABLED): Enable flutter detection end events as an interrupt or wake up source.

FLSTARTIEN

Flutter Start Interrupt Enable.

0 (DISABLED): Disable flutter detection start events as an interrupt or wake up source.

1 (ENABLED): Enable flutter detection start events as an interrupt or wake up source.

IN0

Integrator 0 Output.

0 (LOW): The integrator 0 output is low.

1 (HIGH): The integrator 0 output is high.

IN1

Integrator 1 Output.

0 (LOW): The integrator 1 output is low.

1 (HIGH): The integrator 1 output is high.

IN0PREV

Previous Integrator 0 Output.

0 (LOW): The previous integrator 0 output was low.

1 (HIGH): The previous integrator 0 output was high.

IN1PREV

Previous Integrator 1 Output.

0 (LOW): The previous integrator 1 output was low.

1 (HIGH): The previous integrator 1 output was high.

STATE

Pulse Counter State.

0 (ST0): The pulse counter is in state 0.

1 (ST1): The pulse counter is in state 1.

2 (ST2): The pulse counter is in state 2.

3 (ST3): The pulse counter is in state 3.

DIRF

Direction Flag.

0 (COUNTER_CLOCKWISE): The current direction is counter-clockwise.

1 (CLOCKWISE): The current direction is clockwise.

FLF

Flutter Detected Flag.

0 (NOT_SET): The switch operates normally.

1 (SET): A flutter event was detected.

DIRHIST

Direction History .

CMP0OUT

Comparator 0 Output.

0 (LOW): The output of comparator 0 is low.

1 (HIGH): The output of comparator 0 is high.

CMP1OUT

Comparator 1 Output.

0 (LOW): The output of comparator 1 is low.

1 (HIGH): The output of comparator1 is high.